7
Rear Left Burner (semi-rapid)
Heat Input 2.0 kW
Front Left Burner (auxiliary)
Heat Input 1.0 kW
Rear Right Burner (semi-rapid)
Heat Input 2.0 kW
Front Right Burner: (Triple-crown)
Heat Input 4.0 kW
Instructions for the Installer
Engineers technical data
Overall dimensions
Width: 580 mm.
Depth: 510 mm.
Cut out dimensions
Width: 560 mm.
Depth: 480 mm.
Supply connections
Gas:
RC 1/2 inch (1/2 inch male) Rear right hand corner
Electric:
220 V~ 50 Hz supply, 3 core flexible cable with non
rewireable plug.
Burner Dia. Tap By-pass
1/100 mm
Auxiliary 28
Semi-rapid 32
Triple crown 56
Aeration adjustment none
BURNER TRIPLE CROWN SEMI-RAPID AUXILIARY
(medium) (small)
POSITION MAX MIN MAX MIN MAX MIN
NOMINAL THERMAL
POWER kW 4.0 1.2 2.0 0.45 1.0 0.33
NOMINAL FLOW
RATE m
3
/h 0.381 0.114 0.190 0.043 0.095 0.031
NOZZLE REFERENCE 146 Adjust. 96 Adjust. 70 Adjust.
NOMINAL THERMAL
POWER kW 4.0 1.2 2.0 0.45 1.0 0.33
NOMINAL FLOW
RATE g/h 288 86 144 32 72 24
NOZZLE REFERENCE 98 56 71 32 50 28
NATURAL GAS
20 mbar
TYPE OF
GAS
Characteristics
LPG GAS
28-30/37 mbar
1/100 mm
1/100 mm
VALUE = 49.92 MJ/Kg
VALUE = 37.78 MJ/m
3
Ws - 50.7 MJ/ m
3
APPLIANCE CLASS : 3
APPLIANCE GAS SUPPLY: gas LPG 28-30 / 37mbar
Comentarios a estos manuales